翻訳と辞書
Words near each other
・ Vinícius Goes Barbosa de Souza
・ Vinícius Lopes
・ Vinícius Lopes Laurindo
・ Vinu
・ Vinu Chakravarthy
・ Vinu Mohan
・ Vinu Udani Siriwardhana
・ Vinubhai Patel
・ Vinuesa
・ Vinukonda
・ Vinukonda (Assembly constituency)
・ Vinul Mare River
・ Vinul Mic River
・ Vinul River
・ Vinum
Vinum volume manager
・ Vinutha Lal
・ Vinux
・ Vinya Ariyaratne
・ Vinyali
・ Vinyan
・ Vinyard
・ Vinyl
・ Vinyl (1965 film)
・ Vinyl (2000 film)
・ Vinyl (2012 film)
・ Vinyl (disambiguation)
・ Vinyl (Dramarama album)
・ Vinyl (EP)
・ Vinyl (TV series)


Dictionary Lists
翻訳と辞書 辞書検索 [ 開発暫定版 ]
スポンサード リンク

Vinum volume manager : ウィキペディア英語版
Vinum volume manager

Vinum, is a logical volume manager, also called software RAID, allowing implementations of the RAID-0, RAID-1 and RAID-5 models, both individually and in combination. Vinum is part of the base distribution of the FreeBSD operating system. Versions exist for NetBSD, OpenBSD and DragonFly BSD. Vinum source code is currently maintained in the FreeBSD source tree. Vinum supports RAID levels 0, 1, 5, and JBOD. Vinum is invoked as gvinum (GEOM Vinum) on FreeBSD version 5.4 and up.
==Software RAID vs. Hardware RAID==
The distribution of data across multiple disks can be managed by either dedicated hardware or by software. Additionally, there are hybrid RAIDs that are partly software- and partly hardware-based solutions.
With a software implementation, the operating system manages the disks of the array through the normal drive controller (ATA, SATA, SCSI, Fibre Channel, etc.). With present CPU speeds, software RAID can be faster than hardware RAID.
A hardware implementation of RAID requires at a minimum a special-purpose RAID controller. On a desktop system, this may be a PCI expansion card, or might be a capability built into the motherboard. In larger RAIDs, the controller and disks are usually housed in an external multi-bay enclosure. This controller handles the management of the disks, and performs parity calculations (needed for many RAID levels). This option tends to provide better performance, and makes operating system support easier.
Hardware implementations also typically support hot swapping, allowing failed drives to be replaced while the system is running. In rare cases hardware controllers have become faulty, which can result in data loss. Hybrid RAIDs have become very popular with the introduction of inexpensive hardware RAID controllers. The hardware is a normal disk controller that has no RAID features, but there is a boot-time application that allows users to set up RAIDs that are controlled via the BIOS. When any modern operating system is used, it will need specialized RAID drivers that will make the array look like a single block device. Since these controllers actually do all calculations in software, not hardware, they are often called "fakeraids". Unlike software RAID, these "fakeraids" typically cannot span multiple controllers.

抄文引用元・出典: フリー百科事典『 ウィキペディア(Wikipedia)
ウィキペディアで「Vinum volume manager」の詳細全文を読む



スポンサード リンク
翻訳と辞書 : 翻訳のためのインターネットリソース

Copyright(C) kotoba.ne.jp 1997-2016. All Rights Reserved.